The secret to changing the service life of diesel generator sets from 2 years to 10 years

In today’s industrial field, diesel generator sets, as an indispensable power supply source, have become the focus of attention for many enterprises due to their durability and long lifespan. Why does your diesel generator set have a lifespan of only 2 years, while others can last for over 10 years? The horse racing power generator set summarizes the secret of diesel generator set’s service life changing from 2 years to 10 years.

1. Grinding

Run in is the foundation for extending the service life of diesel generators. Whether it is a new engine or a overhauled engine, it must be run in according to regulations before it can be put into normal operation.

2. Feet

If there is sufficient oil, water, and air supply to the generator set, insufficient or interrupted oil supply can cause poor lubrication of the engine, severe wear of the body, and even tile burning; If the coolant is insufficient, it will cause the generator set to overheat, reduce power, intensify wear, and shorten its service life; If the air supply is not timely or interrupted, there will be difficulties in starting, poor combustion, decreased power, and the engine cannot operate normally.

3. Net

Clean oil, clean water, clean air, and clean engine body. If diesel and engine oil are not pure, it will cause wear and tear on the mating body, increase the mating clearance, cause oil leakage and dripping, reduce the fuel supply pressure, increase the clearance, and even cause serious faults such as oil circuit blockage, shaft holding, and tile burning; If there is a large amount of dust in the air, it will accelerate the wear of cylinder liners, pistons, and piston rings; If the cooling water is not pure, it will cause the cooling system to be blocked by scale, hinder engine heat dissipation, deteriorate lubrication conditions, and cause severe wear on the engine body; If the surface of the body is not clean, it will corrode the surface and shorten its service life.

4. Adjustment

The valve clearance, valve timing, fuel supply advance angle, injection pressure, and ignition timing of the engine should be checked and adjusted in a timely manner to ensure that the engine is in good condition, in order to save fuel and extend its service life.

5. Inspection

Regularly check the fastening parts. Due to the impact of vibration and uneven load during the use of diesel engines, bolts and nuts are prone to loosening. The adjustment bolts of each part should be checked to avoid accidents that may damage the machine body due to looseness.

6. Use

Correct use of diesel generators. Before use, all lubricated parts such as shafts and tiles should be lubricated. After starting, the power generation should be resumed when the water temperature is above 40 ℃. Long term overloading or low-speed work is strictly prohibited. Before shutting down, the load should be unloaded to reduce the speed. After parking in winter, wait until the water temperature drops to 50 ℃ before draining the cooling water (except for engines that have been filled with antifreeze). It is important to maintain the engine regularly to keep the machine running in good condition. Be diligent in observation and inspection, identify faults, and promptly troubleshoot them.

Never operate under overload or ultra-low load. The appropriate load operation should be at 80% load of the generator set, which is reasonable.

The current diesel generator set market is mixed with good and bad, and there are even many informal small workshops in the market. Therefore, when purchasing diesel generator sets, it is necessary to consult professional manufacturers, including product configuration and price, after-sales service projects, etc. We guarantee the quality of our products and will definitely choose OEM manufacturers for generators. We refuse to refurbish machines or second-hand phones.


Post time: Jul-26-2024